Filtration installation UV100-40M
TU 3666-006-49652808-03
The unit is designed to cleansing process water from mechanical entrained solid in the reservoir pressure maintenance system of the oil industry.
It can be used to protect pumping and other equipment in technological installations of the oil and gas industry. Installed on the SPS inlet manifold. The operation of modules A and B is alternating.
CIP flushing of the filter of module A (B) by counterflow from module B (A).
The operating mode is continuous.
Replacement of the filter mesh – within 10 minutes without the use of tools.
![]() UV 100 – 40M |
![]() Filters |
Specifications | ||
Nominal pressure (РN), MPa, no more | 4 (40) | |
Nominal bore (DN), mm | 100 | |
The size of the captured solid particles, μm | > 50 * | |
Temperature limits: | ambient air, ºС | -40 … + 40 |
water, ºС | No more than 80 | |
Dimensions, mm | length | 1186 |
width | 760 | |
height | 1430 | |
Weight, kg | 385 |
![]() |
![]() |